Descripción General | |
---|---|
Presentación | Highly efficient, easy-to-deploy 75kW, 208V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5×8 start-up service. |
Tiempo de Entrega | Suele entregarse en el plazo de 2 semanas |
General | |
equipo suministrado | Dust filter EcoStruxure IT ready (UPS)Installation guide Gestión de redes integrada Los módulos de potencia se despachan instaladosStart-up service |
Tolerancia de tensión de bypass | +/- 10 % |
redundant | No |
UPS size | WS |
Físico | |
acabado exterior | Gloss level 85% |
color | White (RAL 9003) |
profundidad | 84.7 cm |
altura | 148.5 cm |
peso del producto | 290 kg |
anchura | 52.1 cm |
Entrada | |
Frecuencia asignada de empleo | 40…70 Hz |
barras de separación | 177…239 V 208 V |
Otras tensiones de entrada | 200 V220 V |
Corriente máxima de entrada | 269 A |
Nivel máximo de régimen en cortocircuito (IOC) | 65 kA |
Distorsión armónica total de entrada: | Inferior al 3% para plena carga |
tensión de entrada | 3 fases |
load power factor | Desde 0.7 en adelantos hasta 0.7 en retardos sin reducción de la capacidad nominal |
Salida | |
potencia nominal en W | 75000 W |
Máxima potencia configurable (vatios) | 75000 W |
Frecuencia de salida (sincronizada a red eléctrica principal) | 50 Hz sync to mains 60 Hz sync to mains 50 Hz +/- 0,1% para 50Hz nominales no sincronizada 60 Hz +/- 0,1% para 60Hz nominales no sincronizada |
crest factor ((*)) | 2,5 |
Topología | Doble conversión en línea |
Tipo de forma de onda | Onda senoidal |
tolerancia de tensión de salida | +/-1% after 50ms |
Funcionamiento con sobrecarga | 10 minutos al 125% y 60 segundos al 150% |
bypass type | Desviación estática incorporada |
curve equation | Efficiency |
curve fixed loss | 0.0082 |
curve load maximum | 100 % |
curve load minimum | 1 % |
curve proportional loss | 0.0141 |
curve square loss | 0.0415 |
curve X-axis maximum | 100 % |
curve test cond ID | Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with 208V 60Hz input and 208V 60Hz balanced resistive load (PF = 1.0) output. |
curve X-axis minimum | 0 % |
curve X-axis title | Load |
curve X-axis units | Percentage |
curve Y-axis maximum | 100 % |
curve Y-axis minimum | 50 % |
curve Y-axis title | Efficiency |
curve Y-axis units | Percentage |
graph display | 1 |
output voltage | 208 V 3 fases |
Maximum configurable power in VA | 75000 VA |
potencia nominal en VA | 75000 VA |
Conformidad | |
normas | IEC 62040-1-1IEC 62040-2UL 1778 5ta ediciónFCC parte 15 clase AIEC 60721-4-2 Nivel 2M2De conformidad con el estándar UL 924 |
Ambiental | |
temperatura ambiente de funcionamiento | 0…40 °C |
Humedad relativa | 0…95 % non-condensing |
altitud máxima de funcionamiento | 0…3300 ft |
temperatura ambiente de almacenamiento | -25…55 °C |
Humedad relativa de almacenamiento | 10…80 % Sin condensación |
nivel acústico | 68 dBA |
Disipación térmica en línea | 16137 Btu/h |
show note OP temperature | No |
grado de protección IP | IP21 |
Comunicaciones y manejo | |
Panel de control | Interfaz para el usuario de pantalla lcd táctil |
Alarma audible | Alarmas sonoras y visibles priorizadas por severidad |
Packing Units | |
Paquete 1 Peso | 315 kg |
Paquete 1 Altura | 1680 mm |
Paquete 1 ancho | 640 mm |
Paquete 1 Largo | 990 mm |
Garantía contractual | |
Periodo de garantía | 1 year on-site repair or replace with factory authorized Start-Up |